Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 882
Filtrar
1.
Abdom Radiol (NY) ; 49(4): 1223-1230, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38383816

RESUMO

PURPOSE: To describe the technique and evaluate the performance of MRI-guided transgluteal in-bore-targeted biopsy of the prostate gland under local anesthesia in patients without rectal access. METHODS: Ten men (mean age, 69 (range 57-86) years) without rectal access underwent 13 MRI-guided transgluteal in-bore-targeted biopsy of the prostate gland under local anesthesia. All patients underwent mp-MRI at our institute prior to biopsy. Three patients had prior US-guided transperineal biopsy which was unsuccessful in one, negative in one, and yielded GG1 (GS6) PCa in one. Procedure time, complications, histopathology result, and subsequent management were recorded. RESULTS: Median interval between rectal surgery and presentation with elevated PSA was 12.5 years (interquartile range (IQR) 25-75, 8-36.5 years). Mean PSA was 11.9 (range, 4.8 -59.0) ng/ml and PSA density was 0.49 (0.05 -3.2) ng/ml/ml. Distribution of PI-RADS v2.0/2.1 scores of the targeted lesions were PI-RADS 5-3; PI-RADS 4-6; and PI-RADS 3-1. Mean lesion size was 1.5 cm (range, 1.0-3.6 cm). Median interval between MRI and biopsy was 5.5 months (IQR 25-75, 1.5-9 months). Mean procedure time was 47.4 min (range, 29-80 min) and the number of cores varied between 3 and 5. Of the 13 biopsies, 4 yielded clinically significant prostate cancer (csPca), with a Gleason score ≥ 7, 1 yielded insignificant prostate cancer (Gleason score = 6), 7 yielded benign prostatic tissue, and one was technically unsuccessful. 3/13 biopsies were repeat biopsies which detected csPCa in 2 out of the 3 patients. None of the patients had biopsy-related complication. Biopsy result changed management to radiation therapy with ADT in 2 patients with the rest on active surveillance. CONCLUSION: MRI-guided transgluteal in-bore-targeted biopsy of the prostate gland under local anesthesia is feasible in patients without rectal access.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Neoplasias da Próstata , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Próstata/diagnóstico por imagem , Próstata/patologia , Imageamento por Ressonância Magnética/métodos , Antígeno Prostático Específico , Anestesia Local , Biópsia Guiada por Imagem/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Estudos Retrospectivos
2.
Fr J Urol ; 34(1): 102547, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37858376

RESUMO

BACKGROUND: MRI-guided biopsy (MGB) contributes to the diagnosis of clinically significant Prostate Cancer (csPCa). However, there are no clear recommendations for the management of men after a negative MGB. The aim of this study was to assess the risk of csPCa after a first negative MGB. METHODS: Between 2014 and 2020, we selected men with a PI-RADS score ≥ 3 on MRI and a negative MGB (showing benign findings) performed for suspected prostate cancer. MGB (targeted and systematic biopsies) was performed using fully integrated mobile fusion imaging (KOELIS). The primary endpoint was the rate of csPCa (defined as an ISUP grade ≥ 2) diagnosed after a first negative MGB. RESULTS: A total of 381 men with a negative MGB and a median age of 65 (IQR: 59-69, range: 46-85) years were included. During the median follow-up of 31 months, 124 men (32.5%) had a new MRI, and 76 (19.9%) were referred for a new MGB, which revealed csPCa in 16 (4.2%) of them. We found no statistical difference in the characteristics of men diagnosed with csPCa compared with men with no csPCa after the second MGB. CONCLUSION: We observed a risk of significant prostate cancer in 4% of men two years after a negative MRI-guided biopsy. Performing a repeat MRI could improve the selection of men who will benefit from a repeat MRI-guided biopsy, but a clear protocol is needed to follow these patients.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Neoplasias da Próstata , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Biópsia Guiada por Imagem/efeitos adversos , Ultrassonografia de Intervenção/métodos , Imagem por Ressonância Magnética Intervencionista/métodos
3.
World J Urol ; 41(12): 3867-3876, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37823940

RESUMO

PURPOSE: Transperineal mpMRI-targeted fusion prostate biopsies (TPFBx) are recommended for prostate cancer diagnosis, but little is known about their learning curve (LC), especially when performed under local anaesthesia (LA). We investigated how operators' and institutions' experience might affect biopsy results. METHODS: Baseline, procedure and pathology data of consecutive TPFBx under LA were prospectively collected at two academic Institutions, from Sep 2016 to May 2019. Main inclusion criterion was a positive MRI. Endpoints were biopsy duration, clinically significant prostate cancer detection rate on targeted cores (csCDR-T), complications, pain and urinary function. Data were analysed per-centre and per-operator (with ≥ 50 procedures), comparing groups of consecutive patient, and subsequently through regression and CUSUM analyses. Learning curves were plotted using an adjusted lowess smoothing function. RESULTS: We included 1014 patients, with 27.3% csCDR-T and a median duration was 15 min (IQR 12-18). A LC for biopsy duration was detected, with the steeper phase ending after around 50 procedures, in most operators. No reproducible evidence in favour of an impact of experience on csPCa detection was found at operator's level, whilst a possible gentle LC of limited clinical relevance emerged at Institutional level; complications, pain and IPSS variations were not related to operator experience. CONCLUSION: The implementation of TPFBx under LA was feasible, safe and efficient since early phases with a relatively short learning curve for procedure time.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Masculino , Humanos , Próstata/patologia , Curva de Aprendizado , Anestesia Local , Estudos Prospectivos , Imagem por Ressonância Magnética Intervencionista/métodos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Dor
4.
Urology ; 177: 122-127, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37121355

RESUMO

OBJECTIVE: To examine the extent to which the urologist performing biopsy contributes to variation in prostate cancer detection during fusion-guided prostate biopsy. METHODS: All men in the Michigan Urological Surgery Improvement Collaborative (MUSIC) clinical registry who underwent fusion biopsy at Michigan Medicine from August 2017 to March 2019 were included. The primary outcomes were clinically significant cancer detection rate (defined as Gleason Grade ≥2) in targeted cores and clinically significant cancer detection on targeted cores stratified by PI-RADS score. Bivariate and multivariable logistic regression analyses were performed. RESULTS: A total of 1133 fusion biopsies performed by 5 providers were included. When adjusting for patient age, PSA, race, family history, prostate volume, clinical stage, and PI-RADS score, there was no significant difference in targeted clinically significant cancer detection rates across providers (range = 38.5%-46.9%, adjusted P-value = .575). Clinically significant cancer detection rates ranged from 11.1% to 16.7% in PI-RADS 3 (unadjusted P = .838), from 24.6% to 43.4% in PI-RADS 4 (adjusted P = .003), and from 69.4% to 78.8% in PI-RADS 5 (adjusted P = .766) lesions. CONCLUSION: There was a statistically significant difference in clinically significant prostate cancer detection in PI-RADS 4 lesions across providers. These findings suggest that even among experienced providers, variation at the urologist level may contribute to differences in clinically significant cancer detection rates within PI-RADS 4 lesions. However, the relative impact of biopsy technique, radiologist interpretation, and MR acquisition protocol requires further study.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Neoplasias da Próstata , Masculino , Humanos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética/métodos , Urologistas , Estudos Prospectivos , Imagem por Ressonância Magnética Intervencionista/métodos , Biópsia Guiada por Imagem/métodos , Estudos Retrospectivos , Biópsia
5.
Urology ; 177: 109-114, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37059232

RESUMO

OBJECTIVE: To assess the rates of detection of clinically significant prostate cancer (csPCa) and complications associated with transperineal (TP) and transrectal (TR) biopsy approaches to magnetic resonance imaging (MRI)-fusion targeted biopsy. MATERIALS AND METHODS: We retrospectively identified men who underwent TP or TR MRI-targeted biopsy with concurrent systematic random biopsy from August 2020 to August 2021. Primary outcomes were detection rates of csPCa and 30-day complication rates between the 2 MRI-biopsy groups. Data were additionally stratified by prior biopsy status. RESULTS: A total of 361 patients were included in the analysis. No demographic differences were observed. No significant differences were observed between TP and TR approaches on any of the outcomes of interest. TR MRI-targeted biopsies identified csPCa in 47.2% of patients, and TP MRI-targeted biopsies identified csPCa in 48.6% of patients (P = .78). No significant differences were observed in csPCa detection between the 2 approaches for patients on active surveillance (P = .59), patients with prior negative biopsy (P = .34), and patients who were biopsy naïve (P = .19). Complication rates did not vary by approach (P = .45). CONCLUSION: Neither the identification of csPCa by MRI-targeted biopsy nor rates of complications differed significantly based on a TR or TP approach. No differences were seen between MRI-targeted approaches based on prior biopsy or active surveillance status.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Estudos Retrospectivos , Imagem por Ressonância Magnética Intervencionista/métodos , Neoplasias da Próstata/patologia , Biópsia , Imageamento por Ressonância Magnética , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos
6.
Int J Hyperthermia ; 40(1): 2174274, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36775655

RESUMO

OBJECTIVES: The aim of this review was to analyze and summarize the most common adverse events (AEs) and complications after magnetic resonance-guided focused ultrasound (MRgFUS) therapy in uterine fibroids (UFs) and to establish the risk factors of their occurrence. METHODS: We searched for original research studies evaluating MRgFUS therapy in UFs with outcomes containing AEs and/or complications in different databases (PubMed/MEDLINE, SCOPUS, COCHRANE) until March 2022. Reviews, editorials, opinions or letters, case studies, conference papers and abstracts were excluded from the analysis. The systematic literature search identified 446 articles, 43 of which were analyzed. RESULTS: According to available evidence, the overall incidence of serious complications in MRgFUS therapy is relatively low. No AEs/complications were reported in 11 out of 43 analyzed studies. The mean occurrence of all AEs in the analyzed material was 24.67%. The most commonly described AEs included pain, skin burns, urinary tract infections and sciatic neuropraxia. Major AEs, such as skin ulcerations or deep vein thrombosis, occurred in 0.41% of cases in the analyzed material. CONCLUSION: MRgFUS seems to be safe in UF therapy. The occurrence of AEs, especially major ones, is relatively low in comparison with other methods. The new devices and more experience of their users seem to reduce AE rate. The lack of unification in AE reporting and missing data are the main issues in this area. More prospective, randomized studies with unified reporting and long follow-up are needed to determine the safety in a long-term perspective.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Leiomioma , Imagem por Ressonância Magnética Intervencionista , Neoplasias Uterinas , Humanos , Feminino , Estudos Prospectivos , Resultado do Tratamento , Imagem por Ressonância Magnética Intervencionista/métodos , Leiomioma/diagnóstico por imagem , Leiomioma/terapia , Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
8.
Urology ; 171: 164-171, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36206828

RESUMO

OBJECTIVE: To examine the comparative effectiveness of magnetic resonance imaging-ultrasound (MRI-U/S) fusion biopsy and in-bore MRI-targeted biopsy. METHODS: We identified men aged 18-89 with a diagnosis of elevated prostate specific antigen (PSA) or Gleason 6 prostate cancer on active surveillance who underwent MRI-U/S fusion prostate biopsy (12-core + targeted) in the office or in-bore MRI-targeted biopsy (MRI-IB; targeted only). The cancer detection rate (CDR; Gleason 6-10) and clinically significant CDR (csCDR; Gleason 7-10) were compared across biopsy techniques, adjusted for patient and radiographic features. RESULTS: A total of 280 patients (346 lesions) were included, of whom 23.9% were on active surveillance for Gleason 6 prostate cancer. In the per-patient analyses, there was no statistically significant difference in adjusted overall CDR (64.1% vs 54.2%; P = .24) or csCDR (36.5% vs 37.9%; P = .85) between MRI-U/S and MRI-IB biopsy. In the per-lesion analyses, there was no statistically significant difference in adjusted overall CDR (45.7% vs 50.1%; P = .49) between MRI-U/S and MRI-IB biopsy, but MRI-IB biopsy was associated with a higher csCDR than MRI-U/S biopsy (32.8% vs 21.4%; P = .02). CONCLUSION: We observed no statistically significant differences in cancer detection rates between MRI-U/S fusion biopsy and MRI-IB biopsy in per-patient analyses. However, MRI-IB biopsy was associated with higher csCDR when considering targeted biopsy cores only. These results suggest that systematic cores should be obtained when performing MRI-U/S fusion biopsy.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Imagem por Ressonância Magnética Intervencionista/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Biópsia Guiada por Imagem/métodos , Ultrassonografia de Intervenção/métodos , Imageamento por Ressonância Magnética , Gradação de Tumores
9.
Magn Reson Med ; 89(5): 2005-2013, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36585913

RESUMO

PURPOSE: To evaluate a silent MR active catheter tracking sequence that allows conducting catheter interventions with low acoustic noise levels. METHODS: To reduce the acoustic noise associated with MR catheter tracking, we implemented a technique previously used in conventional MRI. The gradient waveforms are modified to reduce the sound pressure level (SPL) and avoid acoustic resonances of the MRI system. The efficacy of the noise reduction was assessed by software-predicted SPL and verified by measurements. Furthermore, the quality of the catheter tracking signal was assessed in a phantom experiment and during interventional cardiovascular MRI sessions targeted at isthmus-related flutter ablation. RESULTS: The maximum measured SPL in the scanner room was 104 dB(A) for real-time imaging, and 88 dB(A) and 69 dB(A) for conventional and silent tracking, respectively. The SPL measured at different positions in the MR suite using silent tracking were 65-69 dB(A), and thus within the range of a normal conversation. Equivalent signal quality and tracking accuracy were obtained using the silent variant of the catheter tracking sequence. CONCLUSION: Our results indicate that silent MR catheter tracking capabilities are identical to conventional catheter tracking. The achieved acoustic noise reduction comes at no penalty in terms of tracking quality or temporal resolution, improves comfort and safety, and can overcome the need for MR-compatible communication equipment and background noise suppression during the actual interventional procedure.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Cateteres , Software , Imagem por Ressonância Magnética Intervencionista/métodos , Imagens de Fantasmas
10.
Pathol Res Pract ; 240: 154188, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36327822

RESUMO

Prostate biopsy is essential in diagnosing prostate cancer. The Prostate Imaging-Reporting and Data System (PI-RADS) and magnetic resonance imaging (MRI)-transrectal ultrasound fusion-guided biopsy are also useful for diagnosis. However, the burden of implementing and maintaining these techniques should be considered. Therefore, we investigated the significance of non-standardized pre-biopsy MRI abnormalities (conditions not in accordance with PI-RADS) and subsequent targeted biopsy. We collected clinicopathological data, including the presence or absence of MRI abnormalities, through biopsies from January 2017 to February 2022 at the Kanagawa Cancer Center and performed statistical analyses. We enrolled in 1086 cases: MRI abnormalities were observed in 861 cases (79.3%). In these 861 cases, the adenocarcinoma detection rate, number of positive cores, and length of the highest Grade Group (GG) lesions were significantly higher. In the multivariate analysis, MRI abnormalities were the most significant factor for detecting adenocarcinoma of ≥GG 2 (odds ratio: 4.52, 95% confidence interval: 3.08-6.63). Targeted biopsy showed a higher percentage of positive cores with ≥GG2 and longer highest GG lesion lengths than systematic biopsy. Furthermore, the highest GG was upgraded in 109 of 788 cases by targeted biopsy. However, several adenocarcinomas (125/788; 15.9%) could not be detected using only targeted biopsy. Non-standardized MRI abnormalities are powerful predictors of cancer and grading. Targeted biopsies based on MRI abnormalities provide several benefits. Owing to the relatively low implementation hurdle, these biopsies may serve as a bridge until the ideal approaches are popularized if the limitations are well understood.


Assuntos
Adenocarcinoma , Imagem por Ressonância Magnética Intervencionista , Neoplasias da Próstata , Masculino , Humanos , Próstata/patologia , Neoplasias da Próstata/patologia , Imagem por Ressonância Magnética Intervencionista/métodos , Imageamento por Ressonância Magnética , Patologistas , Ultrassonografia de Intervenção/métodos , Biópsia Guiada por Imagem/métodos , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Gradação de Tumores
11.
Tomography ; 8(5): 2232-2242, 2022 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-36136883

RESUMO

A combination of surgery and chemotherapy is the most effective treatment available for Malignant Pleural Mesothelioma (MPM). However, both cause significant collateral damage and cannot eliminate residual microscopic disease. This investigation aimed to compare and determine the feasibility of utilizing Radiofrequency Ablation (RFA) and Magnetic-Resonance-guided Focused Ultrasound Surgery (MRgFUS) as alternative treatments for MPM. A large animal tumor model was developed in 13 Yorkshire female pigs using the MSTO211H cell line. Two pigs were initially used to determine the cyclosporine dose required for immunosuppression and tumor development. Subsequently, 11 other pigs underwent tumor development. Of these 11, 2 died during cell inoculation. Small tumor masses and adhesions were present in the other 9, indicating mesothelioma development. Five pigs then received RFA treatment, and 4 pigs received MRgFUS treatment. Tumor model development and effect of the two treatments were examined using MRI and by necropsy. RFA and MRgFUS both successfully ablated approximately the same sized area in the same treatment time. This study demonstrates that RFA and MRgFUS are feasible for tumor debulking, and while MRgFUS requires more pretreatment planning compared to RFA, MRgFUS is a completely noninvasive procedure.


Assuntos
Ablação por Cateter , Ciclosporinas , Imagem por Ressonância Magnética Intervencionista , Mesotelioma Maligno , Animais , Procedimentos Cirúrgicos de Citorredução , Feminino , Imageamento por Ressonância Magnética , Imagem por Ressonância Magnética Intervencionista/métodos , Suínos
12.
Brachytherapy ; 21(6): 814-822, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36155168

RESUMO

BACKGROUND AND PURPOSE: To determine the optimal primary tumor dose for cervical cancer treatment using computed tomography (CT)-based image-guided brachytherapy (IGBT). MATERIALS AND METHODS: We retrospectively reviewed 171 patients with cervical cancer who underwent both external beam radiation therapy (EBRT) and IGBT between May 2015 and December 2019. Majority of EBRT plan included central shielding technique. CT-based IGBT was performed weekly a median of three times. Magnetic resonance imaging preceded the first and third session of IGBT for target delineation. RESULTS: The median age of the patients was 64 years (range: 30-91 years). The median follow-up time for living patients was 43 months (range: 6-76 months). The 3-year local control rates according to the International Federation of Gynecology and Obstetrics (FIGO, 2008) stages were 89%, 100%, 92%, 89%, 78%, and 100% for stages IB, IIA, IIB, IIIA, IIIB, and IVA, respectively. The median EBRT dose to the central pelvis and parametrium/pelvic wall was 41.4 Gy and 50.4 Gy, respectively. Patients who received a cumulative 2 Gy equivalent dose (EQD2) (α/ß = 10 Gy) of high-risk clinical target volume (HR CTV) D90% ≥ 75 Gy achieved a long-term local control rate of 93%, compared with 80% in those who received <75 Gy (p = 0.02). CONCLUSION: This is one of the largest CT-based IGBT series examining the treatment of cervical cancer based on the tumor dose-volume relationship. An HR CTV D90% ≥75 Gy was significantly associated with favorable local control in this study.


Assuntos
Braquiterapia , Imagem por Ressonância Magnética Intervencionista , Neoplasias do Colo do Útero , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Braquiterapia/métodos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/tratamento farmacológico , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Dosagem Radioterapêutica , Resultado do Tratamento
13.
Radiol Med ; 127(10): 1063-1067, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36018489

RESUMO

Over the last ten years, the number of minimally invasive interventional procedures has been increasing steadily. Magnetic resonance imaging (MRI) is still far less frequently used for image-guided percutaneous procedures or as an intervention method than computed tomography (CT) and ultrasound (US). However, MRI has many advantages, such as lack of ionizing radiation, real-time MR-fluoroscopy placement high resolution, no bone and gas artifacts, the ability to display lesions that are difficult to observe on CT and US visualization of blood vessels without a contrast agent, free selection of imaging planes and in the case of procedures such as thermos or cryoablation it is possible to make an intraprocedural assessment of the process without the application of a contrasting agent (Marini et al. in Diagn Interv Imaging 102: 531-538, 2021; Li et al. in BMC Cancer 21: 366, 2021; Barkhausen et al. in Rofo 189: 611, 2017). Furthermore, in addition to its use in Interventional Radiology, MRI is also becoming a reality in cardiology thanks to the possibility of overcoming all the limits related to the fusion technology used up to now in cardiac ablations (Chubb et al. Arrhythm Electrophysiol Rev 6: 85, 2017). Some suites have been built in Northern Europe and in the United States, but based only on personal experience and industry indication. In our hospital, we have built a new Interventional Magnetic Resonance Imaging Suite (IMRIS), the first in Southern Europe and we have defined what the necessary requirements and equipment were for the safety of the patient and the operator.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Meios de Contraste , Fluoroscopia , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Tomografia Computadorizada por Raios X
14.
Urologie ; 61(10): 1137-1148, 2022 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-36040512

RESUMO

The recommendations on carrying out a multiparametric magnetic resonance imaging (mpMRI) for the primary diagnostics and during active surveillance of prostate cancer, include as a consequence an image-guided sampling from conspicuous areas. In doing so, the information on the localization provided by mpMRI is used for a targeted biopsy of the area suspected of being a tumor. The targeted sampling is mainly performed under sonographic control and after fusion of MRI and ultrasound but can also be (mostly in special cases) carried out directly in the MRI scanner. In an ultrasound-guided biopsy, it is vital to coregister the MR images with the ultrasound images (segmentation of the contour of the prostate and registration of suspect findings). This coregistration can either be carried out cognitively (transfer by the person performing the biopsy alone) or software based. Each method shows specific advantages and disadvantages in the prioritization between diagnostic accuracy and resource expenditure.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Neoplasias da Próstata , Humanos , Biópsia Guiada por Imagem/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Masculino , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos
15.
Ther Adv Cardiovasc Dis ; 16: 17539447221119624, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36039865

RESUMO

BACKGROUND: Cardiac magnetic resonance (CMR) provides excellent temporal and spatial resolution, tissue characterization, and flow measurements. This enables major advantages when guiding cardiac invasive procedures compared with X-ray fluoroscopy or ultrasound guidance. However, clinical implementation is limited due to limited availability of technological advancements in magnetic resonance imaging (MRI) compatible equipment. A systematic review of the available literature on past and present applications of interventional MR and its technology readiness level (TRL) was performed, also suggesting future applications. METHODS: A structured literature search was performed using PubMed. Search terms were focused on interventional CMR, cardiac catheterization, and other cardiac invasive procedures. All search results were screened for relevance by language, title, and abstract. TRL was adjusted for use in this article, level 1 being in a hypothetical stage and level 9 being widespread clinical translation. The papers were categorized by the type of procedure and the TRL was estimated. RESULTS: Of 466 papers, 117 papers met the inclusion criteria. TRL was most frequently estimated at level 5 meaning only applicable to in vivo animal studies. Diagnostic right heart catheterization and cavotricuspid isthmus ablation had the highest TRL of 8, meaning proven feasibility and efficacy in a series of humans. CONCLUSION: This article shows that interventional CMR has a potential widespread application although clinical translation is at a modest level with TRL usually at 5. Future development should be directed toward availability of MR-compatible equipment and further improvement of the CMR techniques. This could lead to increased TRL of interventional CMR providing better treatment.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Animais , Humanos , Imageamento por Ressonância Magnética , Imagem por Ressonância Magnética Intervencionista/métodos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Tecnologia
16.
Arch Ital Urol Androl ; 94(2): 155-159, 2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35775338

RESUMO

INTRODUCTION: To evaluate clinical complications following transperineal prostate biopsy in 8.500 patients. MATERIALS AND METHODS: From January 2000 to January 2022, 8,500 men (median age: 62.8 years) underwent transperineal prostate biopsy; since 2011, 1,850 patients were submitted to mpMRI and in the presence of a PI-RADS score ≥ 3, a transperineal targeted biopsy was added to systematic prostate biopsy (4 cores). All patients underwent antibiotic prophylaxis (2000-2011: levoxacin 500 tablet; 2012-2022: 2 grams intravenous of cefazolin). Among 8.500 men 1.350 (15.8%) vs. 4.520 (53.3%) vs. 2.630 (30.9%) underwent 12 vs. 18 vs. > 24 needle cores, respectively. The prostate biopsy-related complications were evaluated within 20 days from prostate biopsy; the number of patients who needed hospital admission or emergency department visit (EDV) was recorded. RESULTS: Prostate cancer was found in 3.150/8.500 (37.1%) patients; overall, hospital admission and EDV were equal to 1.5% and 8.9% and the side effects were directly correlated with the number of needle cores resulting equal to 17.4% (12 cores), 38.7% (18 cores) and 55.3% (> 24 cores) (p = 0.001). Hospital admission and EDV in men who underwent 12 vs. 18 vs. > 24 cores occurred in 1.5% and 7.4% vs. 1.4% and 8.7% vs. 1.7% and 10.6% (p > 0.05), respectively. CONCLUSIONS: Clinical complications following transperineal prostate biopsy involved 35.9% of the patients but only 1.5% of them required hospital admission; urinary tract infection with fever was the most frequent cause of hospital recovery (33.4% of the cases), but none of the patients developed sepsis.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Neoplasias da Próstata , Humanos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Masculino , Pessoa de Meia-Idade , Morbidade , Próstata/patologia , Neoplasias da Próstata/patologia
17.
J Cardiovasc Magn Reson ; 24(1): 32, 2022 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-35650624

RESUMO

INTRODUCTION: Cardiovascular magnetic resonance (CMR)-guided cardiac catheterization is becoming more widespread due to the ability to acquire both functional CMR measurements and diagnostic catheterization data without exposing patients to ionizing radiation. However, the real-time imaging sequences used for catheter guidance during these procedures are limited in resolution and the anatomical detail they can provide. In this study, we propose a passive catheter tracking approach which simultaneously improves catheter tracking and visualization of the anatomy. METHODS: 60 patients with congenital heart disease underwent CMR-guided cardiac catheterization on a 1.5T CMR scanner (Ingenia, Philips Healthcare, Best the Netherlands) using the Philips iSuite system. The proposed T1-overlay technique uses a commercially available heavily T1-weighted sequence to image the catheter, and overlays it on a high-resolution 3D dataset within iSuite in real-time. Suppressed tissue in the real-time images enables the use of a thick imaging slab to assist in tracking of the catheter. Improvement in catheter visualization time was compared between T1-overlay and the conventional invasive CMR (iCMR) balanced steady state free precession (bSSFP) sequence. This technique also enabled selective angiography visualization for real-time evaluation of blood flow dynamics (such as pulmonary transit time), similar to direct contrast injection under standard fluoroscopy. Estimates of pulmonary transit time using iCMR were validated using x-ray fluoroscopy in 16 patients. RESULTS: The T1-overlay approach significantly increased the time that the catheter tip was kept in view by the technologist compared to the bSSFP sequence conventionally used for iCMR. The resulting images received higher ratings for blood/balloon contrast, anatomy visualization, and overall suitability for iCMR guidance by three cardiologists. iCMR selective angiography using T1-overlay also provided accurate estimates of pulmonary transit time that agreed well with x-ray fluoroscopy. CONCLUSION: We demonstrate a new passive catheter tracking technique using the iSuite platform that improves visualization of the catheter and cardiac anatomy. These improvements significantly increase the time that the catheter tip is seen throughout the procedure. We also demonstrate the feasibility of iCMR selective angiography for the measurement of pulmonary transit time.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Cateterismo Cardíaco/métodos , Cateteres , Humanos , Imagem por Ressonância Magnética Intervencionista/métodos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
18.
BMC Urol ; 22(1): 74, 2022 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-35513861

RESUMO

OBJECTIVES: To investigate the causes of missed diagnosis in mpMRI/TRUS fusion-guided targeted prostate biopsy. METHODS: The clinical data of 759 patients who underwent transperineal prostate biopsy from March 2021 to June 2021 at Nanjing DrumTower Hospital were retrospectively analyzed. Twenty-one patients had MRI contraindications. Ultimately, 738 patients completed mpMRI/TRUS fusion-guided targeted prostate biopsy + 12-core transperineal systematic biopsy after mpMRI and PI-RADS scoring. The pathological diagnoses from targeted and systematic biopsy were compared to evaluate and analyze the reasons for missed diagnoses in targeted biopsy. RESULTS: A total of 388 prostate cancer patients were identified, including 37 (9%) missed diagnoses with targeted biopsy and 44 (11.34%) with systematic biopsy. Between the target biopsy missed diagnosis group and not missed diagnosis group, there was no significant difference in age (71.08 ± 7.11 vs. 71.80 ± 7.94), but PSA (13.63 ± 12.41 vs. 54.54 ± 177.25 ng/ml), prostate volume (61.82 ± 40.64 vs. 44.34 ± 25.07 cm3), PSAD (0.27 ± 0.28 vs. 1.07 ± 2.91), and ISUP grade [1(1) vs. 3(2)] were significantly different. The pathological results of the 37 targeted biopsy missed diagnoses were recompared with MRI: 21 prostate cancers were normal on MRI; 9 cancer areas were abnormal on MRI; and 7 cancer areas on MRI were PI-RADS 3. CONCLUSIONS: Early prostate cancer, large prostate, effect of local anesthesia, doctor-patient cooperation, MRI diagnosis, and operator technology were possible factors for missed diagnosis in targeted biopsy. Improvements imaging technology, greater experience, and personalized biopsy may lead to an accurate pathological diagnosis.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Humanos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Masculino , Diagnóstico Ausente , Estudos Prospectivos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Ultrassonografia de Intervenção/métodos
19.
MAGMA ; 35(4): 523-532, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35596009

RESUMO

Multiparametric MRI of the prostate gland has become the initial evaluation of biopsy naïve men with a clinical suspicion for prostate cancer. PI-RADS 2.1 is a joint initiative and framework for prostate MRI acquisition and reporting, which aims to standardize technique and interpretation across centers. Building upon experience accrued following the introduction of PI-RADS 2.0, version 2.1 provides key updates and important clarifications, although it is intended to be an active document, which continues to be updated. Continued advances in our understanding of prostate cancer and progress in imaging technology will undoubtedly shape future iterations of the reporting system.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Masculino , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
20.
J Urol ; 208(1): 109-118, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35272477

RESUMO

PURPOSE: The aim of our study was to compare infectious complication rates between different prostate biopsy techniques with various number of biopsy cores. MATERIALS AND METHODS: In this retrospective study, all patients from 2 hospitals who underwent prostate biopsy between 2012 and 2019 were identified. Cohorts with different types of prostate biopsies were compiled within these hospitals. Primary outcome measure was any registered infectious complication within 7 days post-biopsy. Secondary outcomes were infectious complications within 30 days, hospitalization and bacteremia. To compare the risk of infection following different prostate biopsy techniques, data was fitted into a logistic regression model adjusting for potential confounders. RESULTS: In total, 4,233 prostate biopsies in 3,707 patients were included. After systematic transrectal ultrasound-guided prostate biopsy (TRUSPB; 12±1.4 biopsy cores), 4.0% (2,607) of all patients had infectious complications within 7 days post-biopsy. Transperineal magnetic resonance imaging (MRI)-ultrasound fusion guided prostate biopsy (16±3.7 biopsy cores) was associated with significantly lower infection rates than systematic TRUSPB (adjusted OR: 0.29 [0.09-0.73] 95% confidence interval [CI]). Transrectal targeted MRI-ultrasound fusion guided prostate biopsy (3.1±0.8 biopsy cores) and transrectal targeted in-bore MRI guided prostate biopsy (2.8±0.8 biopsy cores) also showed fewer infectious complications than systematic TRUSPB (adjusted OR: 0.41 [0.12-1.12] 95% CI and 0.68 [0.37-1.20] 95% CI, respectively). CONCLUSIONS: Transperineal prostate biopsy, or transrectal prostate biopsy with reduced number of biopsy cores, could lower the risk of infectious complications.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Neoplasias da Próstata , Humanos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Masculino , Próstata/patologia , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Ultrassonografia de Intervenção/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...